Siemens InsydeH2O Out-of-bounds Write (CVE-2021-45969)

high Tenable OT Security Plugin ID 501738

Synopsis

The remote OT asset is affected by a vulnerability.

Description

An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 before 05.16.25, 5.2 before 05.26.25, 5.3 before 05.35.25, 5.4 before 05.43.25, and 5.5 before 05.51.25. A vulnerability exists in the SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer (the CommBuffer+8 location).

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://www.insyde.com/security-pledge

https://security.netapp.com/advisory/ntap-20220216-0004/

https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf

Plugin Details

Severity: High

ID: 501738

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 9/26/2023

Updated: 9/27/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.5

CVSS v2

Risk Factor: High

Base Score: 7.2

Temporal Score: 5.3

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2021-45969

CVSS v3

Risk Factor: High

Base Score: 8.2

Temporal Score: 7.1

Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:insyde:insydeh2o:5.1, cpe:/a:insyde:insydeh2o:5.2, cpe:/a:insyde:insydeh2o:5.3, cpe:/a:insyde:insydeh2o:5.4, cpe:/a:insyde:insydeh2o:5.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 1/5/2022

Vulnerability Publication Date: 1/5/2022

Reference Information

CVE: CVE-2021-45969

CWE: 787