Hirschmann HiOS Switches Argument Injection or Modification (CVE-2019-12258)

high Tenable OT Security Plugin ID 502267

Synopsis

The remote OT asset is affected by a vulnerability.

Description

An attacker with the source and destination TCP-port and IP-addresses of a session can inject invalid TCP-segments into the flow, causing the TCP-session to be reset.

An application will see this as an ECONNRESET error message when using the socket after such an attack.

The most likely outcome is a crash of the application reading from the affected socket.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Wind River has produced controls and patches to mitigate the reported vulnerabilities. To obtain patches, email [email protected] and indicate the VxWorks major version for which you need source patches.

For more detailed information on the vulnerabilities and the mitigating controls, please see the Wind River advisory at:
https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/

Additional vendors affected by the reported vulnerabilities have also released security advisories related to their affected products. Those advisories are as follows:

Rockwell Automation (login required) - https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1088561

Xerox - https://security.business.xerox.com/en-us/news/wind-river-vxworks-ipnet-tcp-ip-stack-vulnerabilities/

Dräger – https://static.draeger.com/security

Schneider Electric – https://www.se.com/ww/en/download/document/SESB-2019-214-01/

See Also

https://support2.windriver.com/index.php?page=security-notices

http://www.nessus.org/u?17c9f3ec

http://www.nessus.org/u?c7d3d59d

https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf

https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009

https://security.netapp.com/advisory/ntap-20190802-0001/

https://support.f5.com/csp/article/K41190253

https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf

https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf

https://www.cisa.gov/news-events/ics-advisories/icsa-19-211-0

Plugin Details

Severity: High

ID: 502267

Version: 1.4

Type: remote

Family: Tenable.ot

Published: 6/10/2024

Updated: 6/24/2024

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 5

Temporal Score: 3.7

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P

CVSS Score Source: CVE-2019-12258

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/h:belden:hirschmann_rspe37, cpe:/h:belden:hirschmann_rsp25, cpe:/h:belden:hirschmann_rsp35, cpe:/h:belden:hirschmann_rspe30, cpe:/h:belden:hirschmann_rail_switch_power_smart, cpe:/h:belden:hirschmann_rspe35, cpe:/h:belden:hirschmann_dragon_mach4500, cpe:/h:belden:hirschmann_dragon_mach4000, cpe:/h:belden:hirschmann_eagle_one, cpe:/h:belden:hirschmann_eagle20, cpe:/h:belden:hirschmann_eagle30, cpe:/h:belden:hirschmann_rsp30, cpe:/h:belden:hirschmann_rspe32, cpe:/h:belden:hirschmann_rsp20, cpe:/h:belden:hirschmann_rail_switch_power_lite

Required KB Items: Tenable.ot/Hirschmann

Exploit Ease: No known exploits are available

Patch Publication Date: 8/9/2019

Vulnerability Publication Date: 8/9/2019

Reference Information

CVE: CVE-2019-12258

CWE: 384