Siemens SCALANCE X-200RNA Switch Devices Exposure of Sensitive Information to an Unauthorized Actor (CVE-2016-0800)

medium Tenable OT Security Plugin ID 503125

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A cross-protocol attack was discovered that could allow an attacker to decrypt intercepted TLS sessions by using a server supporting SSLv2 as a Bleichenbacher RSA padding oracle. In order to exploit the vulnerability, the attacker must have network access to the affected devices and must be in a privileged network position.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf

https://support.industry.siemens.com/cs/ww/en/view/109814809/

https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21

Plugin Details

Severity: Medium

ID: 503125

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 3/13/2025

Updated: 3/13/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v3

Risk Factor: Medium

Base Score: 4

Temporal Score: 3.6

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/13/2022

Vulnerability Publication Date: 12/13/2022

Reference Information

CVE: CVE-2016-0800

CWE: 787

ICSA: 22-349-21