Honeywell OPOS Suite Stack Buffer Overflow

high Nessus Plugin ID 80910

Synopsis

The remote host is vulnerable to multiple stack-based buffer overflow vulnerabilities.

Description

The Honeywell OPOS Suite installed on the remote host is prior to version 1.13.4.15. It is, therefore, affected by stack-based buffer overflow vulnerabilities in the bundled 'HWOPOSScale.ocx' and 'HWOPOSSCANNER.ocx' ActiveX controls, due to a failure to check the length of user-supplied input to the Open method. A remote attacker, using a specially crafted web page, can exploit these to execute arbitrary code.

Solution

Upgrade to product version 1.13.4.15 or later.

See Also

https://www.honeywellaidc.com/

https://www.zerodayinitiative.com/advisories/ZDI-14-423/

https://www.zerodayinitiative.com/advisories/ZDI-14-424/

Plugin Details

Severity: High

ID: 80910

File Name: scada_honeywell_opos_hwoposscanner_activex.nbin

Version: 1.278

Type: local

Family: SCADA

Published: 1/22/2015

Updated: 11/12/2024

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 5.8

CVSS v2

Risk Factor: High

Base Score: 7.5

Temporal Score: 5.5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS Score Source: CVE-2014-8269

Vulnerability Information

CPE: cpe:/a:honeywell:opos_suite

Required KB Items: SMB/Registry/Enumerated

Exploit Ease: No known exploits are available

Patch Publication Date: 12/11/2014

Vulnerability Publication Date: 12/11/2014

Reference Information

CVE: CVE-2014-8269

BID: 71642

CERT: 659684