Siemens SCALANCE X Switches Improper Input Validation

high Nessus Network Monitor Plugin ID 720136

Synopsis

A vulnerability has been identified in SCALANCE X switches that could allow an attacker to cause a Denial-of-Service condition.

Description

A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.

Solution

Perform vendor recommended mitigations and apply available vendor upgrades.

See Also

http://www.securityfocus.com/bid/105331,https://ics-cert.us-cert.gov/advisories/ICSA-18-254-05,https://cert-portal.siemens.com/productcert/pdf/ssa-447396.pdf

Plugin Details

Severity: High

ID: 720136

Family: SCADA

Published: 5/8/2019

Updated: 9/30/2019

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v2

Risk Factor: High

Base Score: 7.8

Temporal Score: 5.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS v3

Risk Factor: High

Base Score: 8.6

Temporal Score: 7.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

Patch Publication Date: 9/11/2018

Vulnerability Publication Date: 9/11/2018

Reference Information

CVE: CVE-2018-13807

BID: 105331