Ecava IntegraXor < 3.71.4200 Directory Traversal

high Nessus Network Monitor Plugin ID 8399

Synopsis

A vulnerable version of Ecava IntegraXor has been detected.

Description

Ecava IntegraXor versions prior to 3.7.4200 are affected by a directory traversal vulnerability in the ActiveX file 'igcom.dll'. User-supplied input is not properly validated and can allow an attacker to overwrite arbitrary files.

Solution

Upgrade to IntegraXor version 3.7.4200.0 or later.

See Also

http://www.nessus.org/u?063b0edb

https://ics-cert.us-cert.gov/advisories/ICSA-12-083-01

Plugin Details

Severity: High

ID: 8399

Family: SCADA

Published: 9/22/2014

Updated: 3/6/2019

Nessus ID: 59325

Risk Information

VPR

Risk Factor: Medium

Score: 5.8

CVSS v2

Risk Factor: High

Base Score: 9.3

Temporal Score: 7.7

Vector: CVSS2#AV:N/AC:M/Au:N/C:C/I:C/A:C

CVSS v3

Risk Factor: High

Base Score: 8.1

Temporal Score: 7.5

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:F/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:ecava:integraxor

Patch Publication Date: 1/27/2012

Vulnerability Publication Date: 3/23/2012

Reference Information

CVE: CVE-2012-0246

BID: 64972