Siemens SIMATIC S7-1500 Cross-site Scripting (CVE-2014-2246)

medium Tenable OT Security Plugin ID 500137

Synopsis

The remote OT asset is affected by a vulnerability.

Description

Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

http://ics-cert.us-cert.gov/advisories/ICSA-14-073-01

http://www.nessus.org/u?a691e748

http://www.securityfocus.com/bid/66201

https://cert-portal.siemens.com/productcert/pdf/ssa-456423.pdf

Plugin Details

Severity: Medium

ID: 500137

Version: 1.7

Type: remote

Family: Tenable.ot

Published: 2/7/2022

Updated: 9/4/2024

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.0

CVSS v2

Risk Factor: Medium

Base Score: 4.3

Temporal Score: 3.2

Vector: CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N

CVSS Score Source: CVE-2014-2246

CVSS v3

Risk Factor: Medium

Base Score: 6.1

Temporal Score: 5.3

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.1.0, cpe:/o:siemens:simatic_s7-1500_cpu_firmware, cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.1.1, cpe:/o:siemens:simatic_s7-1500_cpu_firmware:1.0.1

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 3/16/2014

Vulnerability Publication Date: 3/16/2014

Reference Information

CVE: CVE-2014-2246

CWE: 79