Siemens RUGGEDCOM ROX II Insufficient Verification of Data Authenticity (CVE-2019-17006)

critical Tenable OT Security Plugin ID 501631

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In Network Security Services (NSS) before 3.46, several cryptographic primitives had missing length checks. In cases where the application calling the library did not perform a sanity check on the inputs it could result in a crash due to a buffer overflow.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has released the following update and recommends it be applied:

RUGGEDCOM ROX (products listed above): Update to v2.14.0 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

- Disable IPsec unless the feature is required in the network environment. Note that IPsec is disabled by default.

As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens’ operational guidelines for Industrial Security, and follow the recommendations in the product manuals.

Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity.
For more information see Siemens security advisory SSA-379803

See Also

http://www.nessus.org/u?a21c3fd6

https://bugzilla.mozilla.org/show_bug.cgi?id=1539788

https://security.netapp.com/advisory/ntap-20210129-0001/

https://cert-portal.siemens.com/productcert/pdf/ssa-379803.pdf

https://us-cert.cisa.gov/ics/advisories/icsa-21-040-04

Plugin Details

Severity: Critical

ID: 501631

Version: 1.4

Type: remote

Family: Tenable.ot

Published: 9/14/2023

Updated: 9/4/2024

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 7.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2019-17006

CVSS v3

Risk Factor: Critical

Base Score: 9.8

Temporal Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:ruggedcom_rox_rx1400_firmware, cpe:/o:siemens:ruggedcom_rox_rx5000_firmware, cpe:/o:siemens:ruggedcom_rox_rx1501_firmware, cpe:/o:siemens:ruggedcom_rox_rx1500_firmware, cpe:/o:siemens:ruggedcom_rox_rx1512_firmware, cpe:/o:siemens:ruggedcom_rox_mx5000_firmware, cpe:/o:siemens:ruggedcom_rox_rx1510_firmware, cpe:/o:siemens:ruggedcom_rox_rx1511_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 10/22/2020

Vulnerability Publication Date: 10/22/2020

Reference Information

CVE: CVE-2019-17006

CWE: 345

ICSA: 21-040-04