Siemens SCALANCE X-200RNA Switch Devices Improper Access Control (CVE-2015-5600)

high Tenable OT Security Plugin ID 503109

Synopsis

The remote OT asset is affected by a vulnerability.

Description

The kbdint_next_device function in auth2-chall.c in sshd in OpenSSH through 6.9 does not properly restrict the processing of keyboard- interactive devices within a single connection, which makes it easier for remote attackers to conduct brute-force attacks or cause a denial of service (CPU consumption) via a long and duplicative list in the ssh -oKbdInteractiveDevices option, as demonstrated by a modified client that provides a different password for each pam element on this list.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf

https://support.industry.siemens.com/cs/ww/en/view/109814809/

https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21

Plugin Details

Severity: High

ID: 503109

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 3/13/2025

Updated: 3/13/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v3

Risk Factor: High

Base Score: 8.2

Temporal Score: 7.4

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7, cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/13/2022

Vulnerability Publication Date: 12/13/2022

Reference Information

CVE: CVE-2015-5600