285 | OT Model Name Detection | Nessus Network Monitor | SCADA | | | info |
287 | Microsoft Windows Underlying OS Detection | Nessus Network Monitor | SCADA | | | info |
3555 | TPKT Server Detection | Nessus Network Monitor | SCADA | 11/24/2014 | 3/7/2017 | info |
3853 | Modicon PLC HTTP Server Default Username/Password (SCADA) | Nessus Network Monitor | SCADA | 12/11/2006 | 9/30/2016 | high |
39 | MODBUS/TCP 'Return Query Data' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
700722 | Advantech WebAccess < 8.3.5 Multiple Vulnerabilities (ICSA-19-024-01) | Nessus Network Monitor | SCADA | 5/27/2019 | 5/27/2019 | critical |
71 | Schneider Electric Modicon TSX Micro Ethernet Communication Module Detection | Nessus Network Monitor | SCADA | | | info |
7100 | MODBUS/TCP 'Restart Communications' Function Code Detection | Nessus Network Monitor | SCADA | 2/26/2014 | 8/16/2018 | info |
7104 | MODBUS/TCP 'CANopen' Function Code Detection | Nessus Network Monitor | SCADA | 2/26/2014 | 8/16/2018 | info |
7124 | Progea Movicon Client Detection via UDP | Nessus Network Monitor | SCADA | 6/18/2014 | 8/16/2018 | info |
7125 | Progea Movicon Server Detection via UDP | Nessus Network Monitor | SCADA | 6/18/2014 | 8/16/2018 | info |
7139 | IEC 60870-5-104 Server Detection | Nessus Network Monitor | SCADA | 9/24/2014 | 8/16/2018 | info |
7142 | Progea Movicon < 11.2 Build 1086 Multiple Vulnerabilities | Nessus Network Monitor | SCADA | 9/10/2014 | 8/16/2018 | critical |
7153 | Schneider Electric Modicon TSX Micro PLC Detection | Nessus Network Monitor | SCADA | 11/10/2014 | 8/16/2018 | info |
7156 | TPKT Server Detection | Nessus Network Monitor | SCADA | 11/26/2014 | 8/16/2018 | info |
7157 | COTP Client Detection | Nessus Network Monitor | SCADA | 11/26/2014 | 8/16/2018 | info |
7161 | Multiple Schneider Electric Modicon M340 Ethernet Modules Remote Denial of Service | Nessus Network Monitor | SCADA | 12/3/2014 | 8/16/2018 | medium |
7183 | Saia Burgess Controls PCD Controllers Hard-Coded FTP Credentials Vulnerability | Nessus Network Monitor | SCADA | 12/18/2015 | 8/16/2018 | high |
7190 | Rockwell Automation/Allen-Bradley CompactLogix 1768 Detection | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | info |
7196 | Siemens S7-1200 Series PLC Detection | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | info |
7198 | Rockwell Automation/Allen-Bradley MicroLogix 1100 L16xxx < 10.000 HTTP Remote DoS | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | high |
72 | Ethernet Industrial Protocol (EtherNet/IP) Implicit Message Detection | Nessus Network Monitor | SCADA | | | info |
720001 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720007 | Siemens WinCC and SIMATIC HMI Panels < 11.0.2.1 Client Side File Injection | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720014 | Siemens WinCC and SIMATIC HMI Panels < 11.0.2.1 Multiple Vulnerabilities | Nessus Network Monitor | SCADA | 5/8/2019 | 10/9/2019 | critical |
720028 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720029 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Information Exposure | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720031 | Siemens CP 1604 and CP 1616 Interface Cards < 2.5.2 Improper Access Control | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720032 | Schneider Electric Quantum and Premium PLC CSRF | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720036 | Emerson Multiple RTUs Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720042 | Siemens SCALANCE Multiple Switches Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720047 | Omron NS HMIs 8.1xx <= 8.68x XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | low |
720053 | GE Multilink Swtiches Hardcoded Encryption Key | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720059 | Siemens RUGGEDCOM WIN Multiple Devices Reversible Password Storage | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720066 | Siemens Climatix BACnet/IP Communication Module < 10.34 XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720070 | Rockwell Automation/Allen-Bradley MicroLogix Multiple Devices Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720072 | Rockwell Automation/Allen-Bradley MicroLogix Multiple Devices Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720074 | Honeywell Midas Gas Detectors Path Cleartext Transmission | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720076 | Rockwell Automation/Allen-Bradley MicroLogix 1100 Multiple Devices Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720078 | Rockwell Automation/Allen-Bradley CompactLogix 1769-Lx < 28.011 XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720097 | Emerson DeltaV Wireless I/O Cards (WIOC) 13.3 Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720110 | Siemens Multiple Devices Profinet DCP Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720111 | Siemens Multiple Devices Profinet DCP Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720126 | Rockwell Automation/Allen-Bradley MicroLogix Controllers <= 16.00 Nonce Key Pair Reuse | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720152 | Schneider Electric Modicon M221 < 1.6.2.0 Information Management Error | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720157 | Schneider Electric ETG3000 FactoryCast HMI Gateway <= 1.60 IR 04 Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720166 | Siemens SIMATIC HMI Panels < 15.4 Integrated Webserver URL Redirection | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720168 | Siemens SIMATIC S7-1200 and SIMATIC S7-1500 CPU < 2.6 TCP Connections DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720173 | Emerson Multiple RTUs Debug Service RCE | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720178 | Rockwell Automation RSLinx Classic < 2.58 DOS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |