242 | Siemens ET 200SP CP 1542SP-1 IRC Detection | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | info |
249 | Schneider Electric Magelis XBT HMI Detection | Nessus Network Monitor | SCADA | | | info |
258 | Schneider Electric Modicon Easy M200 PLC Detection | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | info |
263 | Schneider Electric Zelio Logic Modbus Communication Module Detection | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | info |
268 | Schneider Electric Altivar Process ATV900 Series Variable Speed Drive Detection | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | info |
27 | Siemens S7-400 Series PLC Detection | Nessus Network Monitor | SCADA | | | info |
277 | Schneider Electric 15198 PM9C Multi Meter Detection | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | info |
280 | OT Vendor Detection | Nessus Network Monitor | SCADA | | | info |
286 | OT Firmware Version Detection | Nessus Network Monitor | SCADA | | | info |
288 | 3rd Party Info Received | Nessus Network Monitor | SCADA | | | info |
35 | Modicon M340 BMX P34 CPU Module Detection | Nessus Network Monitor | SCADA | 5/13/2019 | 9/30/2019 | info |
36 | Schneider Electric Modicon Premium PLC Detection | Nessus Network Monitor | SCADA | | | info |
38 | Multiple Schneider Electric Modicon M340 Ethernet Modules Remote Denial of Service | Nessus Network Monitor | SCADA | 5/21/2019 | 9/30/2019 | medium |
3850 | Modicon PLC Embedded HTTP Server Detection (SCADA) | Nessus Network Monitor | SCADA | 12/11/2006 | 9/30/2016 | info |
3851 | Modicon PLC Default FTP Password (SCADA) | Nessus Network Monitor | SCADA | 12/11/2006 | 9/30/2016 | high |
3856 | Modicon PLC IO Scan Status Disclosure | Nessus Network Monitor | SCADA | 12/11/2006 | 1/31/2017 | medium |
43 | MODBUS/TCP 'Report Server ID' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
700723 | Advantech WebAccess < 8.3.5 Multiple Vulnerabilities (ICSA-19-092-01) | Nessus Network Monitor | SCADA | 5/27/2019 | 5/27/2019 | critical |
7090 | DNP3/TCP Outstation Detection | Nessus Network Monitor | SCADA | 2/20/2014 | 8/16/2018 | info |
7097 | DNP3/TCP 'Disable Unsolicited Messages' Function Code Detection | Nessus Network Monitor | SCADA | 2/25/2014 | 8/16/2018 | info |
7099 | MODBUS/TCP 'Return Query Data' Function Code Detection | Nessus Network Monitor | SCADA | 2/26/2014 | 8/16/2018 | info |
7103 | MODBUS/TCP 'Report Server ID' Function Code Detection | Nessus Network Monitor | SCADA | 2/26/2014 | 8/16/2018 | info |
7110 | BACnet/IP Protocol Detection | Nessus Network Monitor | SCADA | 5/29/2014 | 8/16/2018 | info |
7113 | Ethernet Industrial Protocol (EtherNet/IP) Implicit Message Detection | Nessus Network Monitor | SCADA | 7/9/2014 | 8/16/2018 | info |
7114 | Ethernet Industrial Protocol (EtherNet/IP) Client Explicit Message Detection | Nessus Network Monitor | SCADA | 7/9/2014 | 8/16/2018 | info |
7115 | Ethernet Industrial Protocol (EtherNet/IP) Server Explicit Message Detection | Nessus Network Monitor | SCADA | 7/9/2014 | 8/16/2018 | info |
7128 | Progea Movicon < 11.4 Build 1150 Information Disclosure Vulnerability | Nessus Network Monitor | SCADA | 6/20/2014 | 8/16/2018 | medium |
7129 | Progea Movicon < 11.3 Memory Corruption Vulnerability | Nessus Network Monitor | SCADA | 7/3/2014 | 8/16/2018 | high |
7131 | WellinTech KingView Client Detection | Nessus Network Monitor | SCADA | 7/23/2014 | 8/16/2018 | info |
7147 | Rockwell Automation/Allen-Bradley MicroLogix 1400 Series A <= 7 and Series B <= 15.000 DNP3 Remote DoS | Nessus Network Monitor | SCADA | 10/20/2014 | 8/16/2018 | high |
7158 | COTP Server Detection | Nessus Network Monitor | SCADA | 11/26/2014 | 8/16/2018 | info |
7189 | Rockwell Automation/Allen-Bradley MicroLogix 1000 Detection | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | info |
7192 | Rockwell Automation/Allen-Bradley CompactLogix 1769 5370 Series Detection | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | info |
7194 | Siemens S7-300 Series PLC Detection | Nessus Network Monitor | SCADA | 4/29/2016 | 8/16/2018 | info |
720000 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720022 | Siemens SIMATIC S7-1200 PLCs 2.x <= 3.0.1 XSS | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720027 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Improper Access Control | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720030 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Improper Access Control | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720033 | Schneider Electric Multiple PLCs Improper Authentication | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720052 | GE Multilink Swtiches Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720057 | Siemens SIMATIC S7-1200 CPUs < 4.1 Open Redirect | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720061 | Siemens RUGGEDCOM WIN Multiple Devices Buffer Overflow | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720062 | Siemens SIMATIC S7-300 CPUs Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720071 | Rockwell Automation/Allen-Bradley MicroLogix Multiple Devices Unrestricted Upload | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720079 | GE Multilink Switches < 5.5.0 Hardcoded Credentials | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |
720083 | Schneider Electric IONXXXX Power Meters 1.1 <= 4.1 CSRF | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720096 | Rockwell Automation/Allen-Bradley Multiple Devices Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | low |
720100 | Rockwell Automation/Allen-Bradley MicroLogix 1400 Series B FRN < 21.2 Denial of Service | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | high |
720105 | Siemens SICAM RTUs SM-2556 COM Modules Authentication Bypass | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | medium |
720114 | Schneider Electric Modicon M241 and M251 PLCs Insufficiently Random Values | Nessus Network Monitor | SCADA | 5/8/2019 | 9/30/2019 | critical |