72558 | 3S CoDeSys Runtime Toolkit NULL 指標解除參照 (未經認證的檢查) | Nessus | SCADA | 2/18/2014 | 5/20/2024 | medium |
87124 | Emerson SM-Ethernet FTP 伺服器預設認證 | Nessus | SCADA | 12/1/2015 | 5/20/2024 | critical |
81376 | Siemens SCALANCE X-200IRT < 5.2.0 工作階段劫持 | Nessus | SCADA | 2/16/2015 | 5/20/2024 | medium |
81591 | Siemens SIMATIC S7-1200 PLC 韌體偵測 | Nessus | SCADA | 3/2/2015 | 5/20/2024 | info |
83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 5/10/2015 | 7/17/2024 | medium |
83467 | 使用中物件類別的 EtherNet/IP CIP 清單 | Nessus | SCADA | 5/14/2015 | 7/17/2024 | info |
77375 | Honeywell FALCON XL Web 控制器多個弱點 | Nessus | SCADA | 8/25/2014 | 5/20/2024 | high |
77376 | CODESYS WAGO WebVisu 偵測 | Nessus | SCADA | 8/25/2014 | 8/25/2014 | info |
90599 | Rockwell Automation MicroLogix 1400 PLC 預設認證 | Nessus | SCADA | 4/20/2016 | 7/17/2024 | critical |
91622 | Cogent DataHub < 6.4.3 OPC 用戶端重新連線飽和遠端 DoS | Nessus | SCADA | 6/15/2016 | 5/20/2024 | medium |
91624 | Cogent DataHub < 6.4.7 傳入的 DDE 連線處理遠端 DoS | Nessus | SCADA | 6/15/2016 | 5/20/2024 | medium |
99168 | Siemens S7 通訊協定支援偵測 | Nessus | SCADA | 4/3/2017 | 7/17/2024 | info |
52051 | Moxa Device Manager Tool MDM2_Gateway 回應遠端溢位 | Nessus | SCADA | 2/21/2011 | 7/31/2024 | high |
125392 | Siemens SIMATIC WinCC (TIA Portal) < 15 Update 4 多個弱點 (SSA-233109) | Nessus | SCADA | 5/24/2019 | 7/31/2024 | high |
23805 | Siemens S7-SCL 開發工具偵測 | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
23806 | Telvent OASys 系統偵測 | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
66761 | Mitsubishi MX Component ActiveX 遠端程式碼執行 | Nessus | SCADA | 6/3/2013 | 7/31/2024 | critical |
70415 | ProSoft RadioLinx ControlScape 安裝偵測 | Nessus | SCADA | 10/14/2013 | 7/31/2024 | info |
117361 | Advantech WebAccess/SCADA 網路服務偵測 | Nessus | SCADA | 9/10/2018 | 7/31/2024 | info |
23802 | 用於 ControlLogix 偵測的 Matrikon OPC Server | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模組 Op-code 3 封包剖析遠端溢位 | Nessus | SCADA | 6/5/2012 | 7/31/2024 | critical |
59500 | WellinTech KingOPCServer 偵測 | Nessus | SCADA | 6/14/2012 | 7/31/2024 | info |
59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 編碼本機認證洩漏 | Nessus | SCADA | 6/14/2012 | 7/31/2024 | high |
59527 | RuggedCom RuggedOS (ROS) Web 型管理介面偵測 | Nessus | SCADA | 6/15/2012 | 7/31/2024 | info |
64487 | RuggedCom RuggedOS < 3.12.1 Web UI 多個安全性弱點 | Nessus | SCADA | 2/6/2013 | 7/31/2024 | critical |
100463 | GE Multilin UR / URPlus / B95Plus 轉送網頁介面偵測 | Nessus | SCADA | 5/26/2017 | 7/31/2024 | info |
120947 | 3S CODESYS Runtime 3.x < 3.5.14.0 存取控制不足弱點 | Nessus | SCADA | 1/3/2019 | 7/31/2024 | critical |
134977 | 3S CODESYS Runtime 3.x < 3.5.14.20 多個弱點 | Nessus | SCADA | 3/30/2020 | 7/31/2024 | critical |
72556 | 3S CODESYS 2.x 開發系統偵測 (經認證的檢查) | Nessus | SCADA | 2/18/2014 | 7/31/2024 | info |
80910 | Honeywell OPOS Suite 堆疊緩衝區溢位 | Nessus | SCADA | 1/22/2015 | 7/31/2024 | high |
81107 | Schneider Electric 多個產品緩衝區溢位 | Nessus | SCADA | 1/30/2015 | 7/31/2024 | high |
81577 | Siemens SIMATIC WinCC (TIA Portal) V13 偵測 | Nessus | SCADA | 3/1/2015 | 7/31/2024 | info |
84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 未受信任的路徑任意程式碼執行 (SSA-451236) | Nessus | SCADA | 7/2/2015 | 7/31/2024 | medium |
91625 | Panasonic Control FPWIN Pro 偵測 | Nessus | SCADA | 6/15/2016 | 7/31/2024 | info |
95714 | Siemens SINEMA Server < 13 SP2 無引號服務路徑本機權限提升 (SSA-701708) | Nessus | SCADA | 12/12/2016 | 7/31/2024 | medium |
59501 | WellinTech KingSCADA 偵測 | Nessus | SCADA | 6/14/2012 | 7/31/2024 | info |
59558 | Measuresoft ScadaPro < 4.0.1.0 service.exe 多個弱點 (經認證的檢查) | Nessus | SCADA | 6/18/2012 | 7/31/2024 | critical |
62965 | IOServer XML Server URI 目錄遊走任意檔案存取 | Nessus | SCADA | 11/19/2012 | 7/31/2024 | medium |
70558 | ClearSCADA Web 伺服器偵測 | Nessus | SCADA | 10/23/2013 | 7/31/2024 | info |
73642 | Advantech WebAccess 已存跨網站指令碼 | Nessus | SCADA | 4/14/2014 | 7/31/2024 | low |
76573 | Triangle MicroWorks SCADA Data Gateway 偵測 (經認證的檢查) | Nessus | SCADA | 7/17/2014 | 7/31/2024 | info |
83917 | WellinTech KingSCADA < 3.1.2.13-EN KAEClientManager Console 遠端驗證認證洩漏 | Nessus | SCADA | 6/1/2015 | 7/31/2024 | medium |
87125 | Emerson SM-Ethernet Web 介面預設認證 | Nessus | SCADA | 12/1/2015 | 7/31/2024 | high |
88412 | iniNet SpiderControl SCADA Editor 偵測 | Nessus | SCADA | 1/27/2016 | 7/31/2024 | info |
88839 | Advantech WebAccess openWidget 指令碼路徑遊走遠端檔案洩漏 | Nessus | SCADA | 2/18/2016 | 7/31/2024 | high |
90001 | PACTware 偵測 | Nessus | SCADA | 3/17/2016 | 7/31/2024 | info |
122186 | AVEVA InduSoft Web Studio / InTouch Edge HMI 命令 66 中存在 RCE 漏洞 | Nessus | SCADA | 2/14/2019 | 7/17/2024 | critical |
130430 | CODESYS Gateway V3 DoS | Nessus | SCADA | 10/31/2019 | 7/17/2024 | high |
130431 | CODESYS Gateway V3 检测 | Nessus | SCADA | 10/31/2019 | 7/17/2024 | info |
104101 | Schneider Electric InduSoft Web Studio < 8.0 SP2 Patch 1 不明远程命令执行 (LFSEC00000121) | Nessus | SCADA | 10/23/2017 | 11/15/2018 | critical |