100462 | GE Multilin UR / URPlus / B95Plus 保护中继加密算法弱点信息泄露 (UR-2017-0001) | Nessus | SCADA | 5/26/2017 | 5/20/2024 | critical |
150962 | CodeMeter Runtime 缓冲区过度读取 (WIBU-210423-01) | Nessus | SCADA | 6/23/2021 | 7/17/2024 | critical |
149308 | CodeMeter Runtime 检测 | Nessus | SCADA | 5/6/2021 | 7/17/2024 | info |
99168 | Siemens S7 协议支持检测 | Nessus | SCADA | 4/3/2017 | 7/17/2024 | info |
52051 | Moxa Device Manager Tool MDM2_Gateway 响应远程溢出 | Nessus | SCADA | 2/21/2011 | 7/31/2024 | high |
23816 | Tamarack IEC 61850 服务器检测 | Nessus | SCADA | 12/11/2006 | 5/20/2024 | info |
23818 | Modbus/TCP 离散量输入访问 | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
23820 | Modicon PLC 嵌入式 HTTP 服务器检测 | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
23822 | Modicon Quantum HTTP 服务器默认凭据 | Nessus | SCADA | 12/11/2006 | 7/17/2024 | high |
23825 | Modicon PLC Modbus 从属模式 SNMP 请求 Modbus 模式远程泄露 | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
58953 | Microsys PROMOTIC < 8.1.5 多种漏洞 | Nessus | SCADA | 5/1/2012 | 5/20/2024 | high |
52994 | Movicon TcpUploadServer 检测 | Nessus | SCADA | 3/25/2011 | 7/17/2024 | info |
63428 | Siemens Automation License Manager 多种漏洞 | Nessus | SCADA | 1/9/2013 | 5/20/2024 | high |
64296 | Schneider Electric Interactive Graphical SCADA System dc.exe 不明缓冲区溢出 | Nessus | SCADA | 1/30/2013 | 5/20/2024 | critical |
72557 | 3S CoDeSys Runtime Toolkit 空指针取消引用(凭据检查) | Nessus | SCADA | 2/18/2014 | 5/20/2024 | medium |
72558 | 3S CoDeSys Runtime Toolkit 空指针取消引用(无凭据检查) | Nessus | SCADA | 2/18/2014 | 5/20/2024 | medium |
73516 | RuggedCom RuggedOS SNMP 协议不明 DoS | Nessus | SCADA | 4/15/2014 | 5/20/2024 | high |
77375 | Honeywell FALCON XL Web 控制器多种漏洞 | Nessus | SCADA | 8/25/2014 | 5/20/2024 | high |
77376 | CODESYS WAGO WebVisu 检测 | Nessus | SCADA | 8/25/2014 | 8/25/2014 | info |
65193 | CoDeSys Gateway 服务检测 | Nessus | SCADA | 3/11/2013 | 7/17/2024 | info |
70530 | Siemens SCALANCE X-200 认证绕过 | Nessus | SCADA | 10/21/2013 | 5/20/2024 | critical |
70592 | KEPServerEX < 5.12.140.0 拒绝服务 | Nessus | SCADA | 10/24/2013 | 5/20/2024 | high |
57600 | Modicon Quantum TFTP 任意文件上传 | Nessus | SCADA | 1/19/2012 | 7/17/2024 | high |
62032 | Sielco Sistemi Winlog < 2.07.17 多种漏洞 | Nessus | SCADA | 9/10/2012 | 5/20/2024 | high |
81591 | Siemens SIMATIC S7-1200 PLC 固件检测 | Nessus | SCADA | 3/2/2015 | 5/20/2024 | info |
83467 | 活动对象类的 EtherNet/IP CIP 列表 | Nessus | SCADA | 5/14/2015 | 7/17/2024 | info |
83302 | Modbus/TCP Report Slave ID | Nessus | SCADA | 5/10/2015 | 7/17/2024 | medium |
91622 | Cogent DataHub < 6.4.3 OPC 客户端重新连接饱和远程 DoS | Nessus | SCADA | 6/15/2016 | 5/20/2024 | medium |
91624 | Cogent DataHub < 6.4.7 传入的 DDE 连接处理远程 DoS | Nessus | SCADA | 6/15/2016 | 5/20/2024 | medium |
90599 | Rockwell Automation MicroLogix 1400 PLC 默认凭据 | Nessus | SCADA | 4/20/2016 | 7/17/2024 | critical |
81376 | Siemens SCALANCE X-200IRT < 5.2.0 中存在会话劫持 | Nessus | SCADA | 2/16/2015 | 5/20/2024 | medium |
87124 | Emerson SM-Ethernet FTP 服务器默认凭据 | Nessus | SCADA | 12/1/2015 | 5/20/2024 | critical |
125392 | Siemens SIMATIC WinCC (TIA Portal) < 15 Update 4 多种漏洞 (SSA-233109) | Nessus | SCADA | 5/24/2019 | 7/31/2024 | high |
23805 | Siemens S7-SCL 开发工具检测 | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
23806 | Telvent OASys 系统检测 | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
66761 | Mitsubishi MX Component ActiveX 远程代码执行 | Nessus | SCADA | 6/3/2013 | 7/31/2024 | critical |
70415 | ProSoft RadioLinx ControlScape 安装检测 | Nessus | SCADA | 10/14/2013 | 7/31/2024 | info |
72556 | 3S CODESYS 2.x 开发系统检测(凭据检查) | Nessus | SCADA | 2/18/2014 | 7/31/2024 | info |
80910 | Honeywell OPOS Suite 堆栈缓冲区溢出 | Nessus | SCADA | 1/22/2015 | 7/31/2024 | high |
81107 | Schneider Electric 多种产品缓冲区溢出 | Nessus | SCADA | 1/30/2015 | 7/31/2024 | high |
81577 | Siemens SIMATIC WinCC (TIA Portal) V13 检测 | Nessus | SCADA | 3/1/2015 | 7/31/2024 | info |
84499 | Siemens SIMATIC ProSave < 1300.100.2201.15 不受信任的路径任意代码执行 (SSA-451236) | Nessus | SCADA | 7/2/2015 | 7/31/2024 | medium |
91625 | Panasonic Control FPWIN Pro 检测 | Nessus | SCADA | 6/15/2016 | 7/31/2024 | info |
95714 | Siemens SINEMA Server < 13 SP2 无引号服务路径本地权限提升 (SSA-701708) | Nessus | SCADA | 12/12/2016 | 7/31/2024 | medium |
117361 | Advantech WebAccess/SCADA Network Service 检测 | Nessus | SCADA | 9/10/2018 | 7/31/2024 | info |
23802 | 用于 ControlLogix 检测的 Matrikon OPC Server | Nessus | SCADA | 12/11/2006 | 7/31/2024 | info |
59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll 模块操作码 3 数据包解析远程溢出 | Nessus | SCADA | 6/5/2012 | 7/31/2024 | critical |
59500 | WellinTech KingOPCServer 检测 | Nessus | SCADA | 6/14/2012 | 7/31/2024 | info |
59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 编码本地凭据泄露 | Nessus | SCADA | 6/14/2012 | 7/31/2024 | high |
59527 | 基于 Web 的 RuggedCom RuggedOS (ROS) 管理界面检测 | Nessus | SCADA | 6/15/2012 | 7/31/2024 | info |