196949 | Rockwell FactoryTalk Historian Installed (Windows) | Nessus | SCADA | 5/14/2024 | 7/24/2024 | info |
196950 | Rockwell FactoryTalk Historian < 9.01 DoS | Nessus | SCADA | 5/14/2024 | 5/15/2024 | high |
176666 | Moxa MXsecurity Series Detection | Nessus | SCADA | 6/5/2023 | 7/24/2024 | info |
183240 | LG LED Assistant Detection | Nessus | SCADA | 10/17/2023 | 7/24/2024 | info |
58991 | RuggedCom RuggedOS Default 'factory' Account Backdoor | Nessus | SCADA | 6/12/2012 | 7/24/2024 | critical |
64630 | Ecava IntegraXor < 4.00.4283 ActiveX Remote Buffer Overflow | Nessus | SCADA | 2/14/2013 | 5/20/2024 | high |
65194 | CoDeSys Unprotected Gateway Service | Nessus | SCADA | 3/11/2013 | 5/20/2024 | high |
59528 | RuggedCom RuggedOS Web-Based Admin Interface Default Credentials | Nessus | SCADA | 6/15/2012 | 7/24/2024 | critical |
59249 | 7-Technologies IGSS < 9.0.0.11291 DLL Loading Arbitrary Code Execution | Nessus | SCADA | 5/23/2012 | 5/20/2024 | high |
59892 | WellinTech KingHistorian Detection | Nessus | SCADA | 7/6/2012 | 7/24/2024 | info |
70556 | Cogent DataHub Tunnel/Mirror Service Detection | Nessus | SCADA | 10/23/2013 | 7/17/2024 | info |
70591 | KEPServerEX Detection | Nessus | SCADA | 10/24/2013 | 7/24/2024 | info |
72486 | Cogent DataHub < 7.3.4 Malformed POST Request Buffer Overflow RCE | Nessus | SCADA | 2/13/2014 | 5/20/2024 | high |
72620 | TURCK BL20/BL67 Hardcoded Admin Account | Nessus | SCADA | 2/10/2014 | 7/17/2024 | critical |
72107 | Ecava IntegraXor < 4.1.4369 Project Directory Information Disclosure | Nessus | SCADA | 1/23/2014 | 5/20/2024 | medium |
72108 | Ecava IntegraXor < 4.1.4390 Buffer Overflow | Nessus | SCADA | 1/21/2014 | 5/20/2024 | high |
70921 | Schneider Electric Accutech Manager 'RFManagerService' SQL Injection | Nessus | SCADA | 11/15/2013 | 7/17/2024 | critical |
73646 | Advantech WebAccess webvact ActiveX Multiple Buffer Overflow Vulnerabilities | Nessus | SCADA | 4/14/2014 | 7/24/2024 | high |
73517 | RuggedCom RuggedOS HTTP Traffic Handling Remote DoS | Nessus | SCADA | 4/15/2014 | 7/24/2024 | medium |
61493 | Sielco Sistemi Winlog Arbitrary File Disclosure | Nessus | SCADA | 8/10/2012 | 5/20/2024 | medium |
57598 | GE D20 Default Credentials | Nessus | SCADA | 1/19/2012 | 5/20/2024 | high |
57602 | Sensitive information can be obtained from the GE D20 Remote Terminal Unit via TFTP | Nessus | SCADA | 1/19/2012 | 7/17/2024 | high |
58796 | Microsys PROMOTIC Detection | Nessus | SCADA | 4/19/2012 | 7/24/2024 | info |
58449 | 7-Technologies AQUIS Unspecified Path Subversion Arbitrary DLL Injection Code Execution | Nessus | SCADA | 3/23/2012 | 7/24/2024 | high |
67144 | Tridium Niagara AX Web Server Multiple Vulnerabilities | Nessus | SCADA | 7/3/2013 | 7/17/2024 | high |
189747 | CyberPower PowerPanel Enterprise Detection | Nessus | SCADA | 1/29/2024 | 7/24/2024 | info |
51360 | Ecava IntegraXor ActiveX save Method Buffer Overflow | Nessus | SCADA | 12/22/2010 | 7/24/2024 | high |
52961 | 7-Technologies / Schneider-Electric IGSS Detection | Nessus | SCADA | 3/24/2011 | 7/24/2024 | info |
52993 | Movicon < 11.2 Build 1084 Multiple Vulnerabilities | Nessus | SCADA | 3/25/2011 | 5/20/2024 | high |
53572 | Automated Solutions Modbus/TCP OPC Server Detection | Nessus | SCADA | 4/27/2011 | 7/24/2024 | info |
53573 | Modbus/TCP Master OPC Server MODBUS Protocol Response Packet Remote Overflow | Nessus | SCADA | 4/27/2011 | 5/20/2024 | high |
47759 | Siemens SIMATIC WinCC Default Password Authentication Bypass | Nessus | SCADA | 7/16/2010 | 7/24/2024 | high |
33169 | CitectSCADA Detection | Nessus | SCADA | 6/13/2008 | 5/24/2023 | info |
56993 | Advantech / BroadWin WebAccess Client 'bwocxrun.ocx ' Multiple Remote Vulnerabilities | Nessus | SCADA | 12/2/2011 | 7/24/2024 | high |
63427 | Siemens Automation License Manager Detection | Nessus | SCADA | 1/9/2013 | 7/24/2024 | info |
62964 | IOServer Detection | Nessus | SCADA | 11/19/2012 | 7/24/2024 | info |
65603 | Schneider Electric Accutech Manager RFManagerService Heap Overflow | Nessus | SCADA | 3/18/2013 | 5/20/2024 | critical |
65656 | Honeywell Multiple Products HscRemoteDepoy.dll ActiveX Control Arbitrary Code Execution | Nessus | SCADA | 3/22/2013 | 7/24/2024 | medium |
66405 | Clorius Controls ISC SCADA Detection | Nessus | SCADA | 5/14/2013 | 7/24/2024 | info |
81789 | Siemens SIMATIC STEP 7 (TIA Portal) Detection | Nessus | SCADA | 3/12/2015 | 7/24/2024 | info |
84566 | Rockwell Automation MicroLogix 1100 PLC Default Credentials | Nessus | SCADA | 7/7/2015 | 7/17/2024 | high |
84570 | Rockwell Automation MicroLogix 1100 PLC < FRN 10.0 Authentication Mechanism DoS | Nessus | SCADA | 7/7/2015 | 7/17/2024 | critical |
76575 | Triangle MicroWorks SCADA Data Gateway < 3.3.729 Heartbeat Information Disclosure (Heartbleed) | Nessus | SCADA | 7/7/2014 | 7/24/2024 | high |
85411 | Advantech WebAccess < 7.2-2013.11.14 Multiple Vulnerabilities | Nessus | SCADA | 8/17/2015 | 7/24/2024 | high |
82665 | WellinTech KingView < 6.53 (2012-10-09) User Credentials Not Securely Hashed | Nessus | SCADA | 4/9/2015 | 7/24/2024 | low |
88414 | iniNet SpiderControl PLC Editor Simatic 6.30.04 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 7/24/2024 | high |
88415 | iniNet SpiderControl SCADA Editor 6.30.01 Local Privilege Escalation | Nessus | SCADA | 1/27/2016 | 7/24/2024 | high |
87891 | Janitza Multiple UMG Devices Remote Debug Interface RCE | Nessus | SCADA | 1/13/2016 | 5/20/2024 | high |
81545 | Siemens SIMATIC STEP 7 (TIA Portal) < 1300.100.2501.1 Multiple Vulnerabilities (SSA-315836) | Nessus | SCADA | 2/26/2015 | 7/24/2024 | medium |
80359 | StruxureWare SCADA Expert ClearSCADA Remote Security Bypass | Nessus | SCADA | 1/5/2015 | 7/17/2024 | medium |