83187 | Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX Object Multiple Buffer Overflows DoS | Nessus | SCADA | 5/1/2015 | 7/24/2024 | high |
89029 | 7-Technologies / Schneider-Electric IGSS ODBC Service Detection | Nessus | SCADA | 2/29/2016 | 7/17/2024 | info |
89030 | 7-Technologies IGSS < 9.0.0.11143 ODBC Invalid Structure RCE | Nessus | SCADA | 2/29/2016 | 5/20/2024 | critical |
89031 | 7-Technologies IGSS < 10.0.0 ODBC Buffer Overflow RCE | Nessus | SCADA | 2/29/2016 | 5/20/2024 | critical |
62439 | Magnum MNS-6K Hardcoded Admin Account | Nessus | SCADA | 10/5/2012 | 5/20/2024 | high |
97666 | Siemens SIMATIC Logon Authentication Bypass | Nessus | SCADA | 3/10/2017 | 7/24/2024 | critical |
97667 | Siemens SIMATIC Logon Detection | Nessus | SCADA | 3/10/2017 | 7/24/2024 | info |
91284 | Moxa NPort Serial-to-Ethernet Server Multiple Vulnerabilities | Nessus | SCADA | 5/20/2016 | 5/20/2024 | critical |
91345 | Allen-Bradley MicroLogix 1400 Multiple Vulnerabilities | Nessus | SCADA | 5/27/2016 | 7/17/2024 | critical |
91384 | MicroLogix 1400 PLC Web Server Multiple Vulnerabilities | Nessus | SCADA | 5/31/2016 | 7/17/2024 | high |
178747 | CyberPower PowerPanel Business Management Use of Default Password (CVE-2023-25131) | Nessus | SCADA | 7/24/2023 | 7/24/2024 | critical |
173829 | Delta Electronics InfraSuite Device Master Gateway Deserialization of Untrusted Data (CVE-2023-1133) | Nessus | SCADA | 4/4/2023 | 7/24/2024 | critical |
106228 | Schneider Electric InduSoft Web Studio / InTouch Machine Edition < 8.1 RCE | Nessus | SCADA | 1/22/2018 | 7/17/2024 | critical |
103533 | Trihedral VTScada 8.x < 11.2.02 Multiple Vulnerabilities | Nessus | SCADA | 9/28/2017 | 5/20/2024 | critical |
103534 | Trihedral VTScada Detection | Nessus | SCADA | 9/28/2017 | 7/17/2024 | info |
109145 | Schneider Electric InTouch Machine Edition Detection | Nessus | SCADA | 4/18/2018 | 7/24/2024 | info |
109146 | Schneider Electric InduSoft Web Studio Detection | Nessus | SCADA | 4/18/2018 | 7/24/2024 | info |
118711 | DNP3 Detection of Device attributes | Nessus | SCADA | 11/2/2018 | 7/17/2024 | info |
119845 | Advantech WebAccess webvrpcs.exe IOCTL 70022 Stack Overflow | Nessus | SCADA | 12/21/2018 | 7/24/2024 | high |
172392 | Contec CONPROSYS HMI System (CHS) Detection | Nessus | SCADA | 3/9/2023 | 7/24/2024 | info |
183239 | LG LED Assistant Path Traversal (CVE-2023-4613) | Nessus | SCADA | 10/17/2023 | 7/24/2024 | critical |
176665 | Moxa MXsecurity Series Hard-coded JWT Key Authentication Bypass (CVE-2023-33236) | Nessus | SCADA | 6/5/2023 | 7/24/2024 | critical |
174122 | Contec CONPROSYS HMI System (CHS) SQL Injection (CVE-2023-1658) | Nessus | SCADA | 4/11/2023 | 7/24/2024 | high |
155947 | CODESYS V3 Web Server Heap-based Buffer Overflow (CVE-2021-33485) | Nessus | SCADA | 12/8/2021 | 7/17/2024 | critical |
162819 | Keysight Technologies Sensor Management Server Deserialization RCE (CVE-2022-1660) | Nessus | SCADA | 7/7/2022 | 7/24/2024 | critical |
170033 | Schneider Electric APC Easy UPS Online Monitoring Software Missing Authentication (CVE-2022-42970) | Nessus | SCADA | 1/13/2023 | 7/24/2024 | critical |
50687 | RealWin < 2.1.10 Multiple Packet Type Processing Overflows | Nessus | SCADA | 11/23/2010 | 5/20/2024 | critical |
53878 | Samsung Data Management Server Default Password (rkwjsdusrnth) for 'root' Account | Nessus | SCADA | 5/11/2011 | 5/20/2024 | critical |
55630 | Sielco Sistemi Winlog Detection | Nessus | SCADA | 7/19/2011 | 7/24/2024 | info |
26066 | Automated Solutions Modbus Slave MiniHMI.exe ActiveX Modbus/TCP Diagnostic Function Arbitrary Code Execution | Nessus | SCADA | 9/19/2007 | 7/24/2024 | high |
149971 | Schneider Electric C-Gate < 2.11.6 Multiple Vulnerabilities | Nessus | SCADA | 5/26/2021 | 7/24/2024 | high |
149307 | CodeMeter Runtime Predictable Encryption Key | Nessus | SCADA | 5/6/2021 | 7/24/2024 | critical |
152098 | CODESYS V2 Web Server Improperly Implemented Security Check (2021-07) | Nessus | SCADA | 7/27/2021 | 7/24/2024 | critical |
141304 | Rockwell Automation FactoryTalk Linx Path Traversal Information Disclosure | Nessus | SCADA | 10/8/2020 | 7/17/2024 | high |
131704 | 3S CODESYS CmpWebServerHandlerV3 Heap-based Buffer Overflow | Nessus | SCADA | 12/4/2019 | 7/24/2024 | critical |
136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 Multiple Vulnerabilities | Nessus | SCADA | 4/30/2020 | 7/24/2024 | critical |
135696 | Rockwell Automation RSLinx Classic < 4.11.00 Local Privilege Escalation | Nessus | SCADA | 4/17/2020 | 7/24/2024 | high |
201196 | Siemens Automation License Manager Path Traversal (CVE-2022-43514) | Nessus | SCADA | 7/1/2024 | 7/24/2024 | critical |
23810 | DNP3 Outstation Unsolicited Messaging Support | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
23815 | SISCO OSI/ICCP Stack Detection | Nessus | SCADA | 12/11/2006 | 7/24/2024 | info |
23817 | Modbus/TCP Coil Access | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
23819 | Modicon Modbus/TCP Programming Function Code Access | Nessus | SCADA | 12/11/2006 | 5/20/2024 | medium |
23821 | Schneider Electric FTP Server Default Credentials | Nessus | SCADA | 12/11/2006 | 5/20/2024 | critical |
23826 | Modicon PLC Web Password Status Disclosure SNMP Request Password Status Remote Disclosure | Nessus | SCADA | 12/11/2006 | 7/17/2024 | medium |
192106 | Milesight MilesightVPN Detection | Nessus | SCADA | 3/14/2024 | 7/24/2024 | info |
192107 | Milesight MilesightVPN Authentication Bypass (CVE-2023-22844) | Nessus | SCADA | 3/14/2024 | 7/24/2024 | critical |
189258 | Rockwell FactoryTalk Services Platform 2.74 Authentication Bypass | Nessus | SCADA | 1/20/2024 | 5/31/2024 | high |
189287 | Rockwell FactoryTalk Activation Manager Installed (Windows) | Nessus | SCADA | 1/22/2024 | 7/24/2024 | info |
189288 | Rockwell FactoryTalk Activation Manager < 4.02 XSS | Nessus | SCADA | 1/22/2024 | 1/23/2024 | medium |
187749 | Rockwell FactoryTalk Services Platform < 3.00 DoS | Nessus | SCADA | 1/9/2024 | 1/22/2024 | high |