Juniper Junos OS Vulnerability (JSA11014)

high Nessus Plugin ID 178669

Synopsis

The remote device is missing a vendor-supplied security patch.

Description

The version of Junos OS installed on the remote host is affected by a vulnerability as referenced in the JSA11014 advisory.

- On High-End SRX Series devices, in specific configurations and when specific networking events or operator actions occur, an SPC receiving genuine multicast traffic may core. Subsequently, all FPCs in a chassis may reset causing a Denial of Service. This issue affects both IPv4 and IPv6. This issue affects: Juniper Networks Junos OS 12.3X48 version 12.3X48-D80 and later versions prior to 12.3X48-D95 on High-End SRX Series. This issue does not affect Branch SRX Series devices. (CVE-2020-1634)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version number.

Solution

Apply the relevant Junos software release referenced in Juniper advisory JSA11014

See Also

http://www.nessus.org/u?64939718

Plugin Details

Severity: High

ID: 178669

File Name: juniper_jsa11014.nasl

Version: 1.0

Type: combined

Published: 7/20/2023

Updated: 7/20/2023

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 4.3

Temporal Score: 3.2

Vector: CVSS2#AV:N/AC:M/Au:N/C:N/I:N/A:P

CVSS Score Source: CVE-2020-1634

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:juniper:junos

Required KB Items: Host/Juniper/model, Host/Juniper/JUNOS/Version

Exploit Ease: No known exploits are available

Patch Publication Date: 4/8/2020

Vulnerability Publication Date: 4/8/2020

Reference Information

CVE: CVE-2020-1634

JSA: JSA11014