PTZOptics Camera Multiple Vulnerabilities (Direct Check)

critical Nessus Plugin ID 210334

Synopsis

A camera is affected by a multiple vulnerabilities.

Description

A PTZOptics camera is vulnerable to CVE-2024-8956 and, therefore, is affected by multiple vulnerabilities:

- PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file. (CVE-2024-8956)

- PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices. (CVE-2024-8957)

Solution

Upgrade to the latest available PTZOptics camera firmware.

See Also

https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/

https://vulncheck.com/advisories/ptzoptics-insufficient-auth

Plugin Details

Severity: Critical

ID: 210334

File Name: ptzoptics_camera_CVE-2024-8956.nbin

Version: 1.5

Type: remote

Family: CGI abuses

Published: 11/5/2024

Updated: 11/22/2024

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: High

Score: 7.7

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 8.3

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2024-8957

CVSS v3

Risk Factor: Critical

Base Score: 9.8

Temporal Score: 9.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:F/RL:O/RC:C

Vulnerability Information

CPE: x-cpe:/h:ptzoptics:camera

Required KB Items: installed_sw/PTZOptics Camera

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 9/17/2024

Vulnerability Publication Date: 9/17/2024

CISA Known Exploited Vulnerability Due Dates: 11/25/2024

Reference Information

CVE: CVE-2024-8956, CVE-2024-8957