Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-41839)

high Tenable OT Security Plugin ID 501719

Synopsis

The remote OT asset is affected by a vulnerability.

Description

An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://www.insyde.com/security-pledge

https://www.insyde.com/security-pledge/SA-2022020

https://security.netapp.com/advisory/ntap-20220217-0016/

https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf

Plugin Details

Severity: High

ID: 501719

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 9/26/2023

Updated: 9/27/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.5

CVSS v2

Risk Factor: Medium

Base Score: 4.6

Temporal Score: 3.4

Vector: CVSS2#AV:L/AC:L/Au:N/C:P/I:P/A:P

CVSS Score Source: CVE-2021-41839

CVSS v3

Risk Factor: High

Base Score: 8.2

Temporal Score: 7.1

Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:insyde:insydeh2o:5.2, cpe:/a:insyde:insydeh2o:5.3, cpe:/a:insyde:insydeh2o:5.1, cpe:/a:insyde:insydeh2o:5.5, cpe:/a:insyde:insydeh2o:5.4

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 2/3/2022

Vulnerability Publication Date: 2/3/2022

Reference Information

CVE: CVE-2021-41839

CWE: 119